Shaping the future of food safety since 2005, bringing together hundreds of food safety professionals from across Europe and around the workd to exchange ideas and gain knowledge about the latest in developments and techniques in food science and safety. The 2023 Symposium includes a vast array of diverse topics and speakers for those working in industry, government and academia. 

Poster Session

Performance Evaluation of Ready-to-Use Culture Media, Easy Plate AC for Enumeration of Aerobic Plate Count in a Broad Range of Foods, Environmental Samples and Pet Foods

Abstract
Introduction: The Ready-to-use (RTU) media Easy Plate AC (Kikkoman Biochemifa Company) provides many benefits including reduced time-to- result, simplicity of us,e and is more sustainable compared to conventional plate count agar. The speed of analysis of the device gives a saving of 24 h over the reference method with results available in 48 h.

Purpose: To evaluate the performance of the RTU device for the enumeration of aerobic count as detailed in the ISO 16140-2 validation protocol.

Methods: The repeatability, accuracy and relative trueness of the RTU device was evaluated during the study across 5 food categories; dairy products, fishery products, produce and fruits, meat and poultry, and multicomponent foods in addition to environmental samples and pet foods. Analysis of the samples was performed according to the manufacturer’s instructions and ISO 4833-1 (2013).

Results: Study results revealed good agreement between the RTU device and the reference method in the 105 samples analyzed in the relative trueness study. During the accuracy profile it was demonstrated that all seven categories passed the 0.5 log acceptability limits or the recalculated limits. Additional studies showed that the RTU device prevented the spread of members of the Bacillus spp. seen on Plate Count Agar.

Significance: Data indicates that the RTU device provides equivalent results to the ISO reference method 4833-1 (2013) for a broad range of foods, environmental samples and pet foods. In addition to the reduced time-to-result compared to PCA, the media allows better colony counting with samples containing Bacillus spp.

Performance Evaluation of Ready-to-Use Culture Media, Easy Plate SA for Enumeration of Staphylococcus aureus in a Broad Range of Foods

Abstract

Introduction: Ready to use (RTU) media offers many advantages to the end user including shorter time-to-result and ease of use as well as being more sustainable. Easy Plate SA (Kikkoman Biochemifa Company) reduces the time of enumeration of Staphylococcus aureus to 24 h, a savings of 24 h compared to the standard ISO 6888-1 protocol.

Purpose: To compare the performance of the RTU device and ISO method 6888-1(2021) for the enumeration of S. aureus in a broad range of foods following the ISO 16140-2 validation protocol.

Methods: This study evaluated the specificity, selectivity, repeatability, accuracy and relative trueness of the RTU device as required by ISO 16140-2. During the study, 225 food samples were analyzed across five food categories: dairy products, fishery products, produce and fruits, meat and poultry and multicomponent foods. All samples were tested according to the manufacturer’s instructions and ISO 6888-1.

Results: Results from the study revealed the RTU device gave comparable results to the reference method across the 75 analyzed in the relative trueness with no evidence of bias between the methods. In the accuracy profile study, all five categories tested satisfied the 0.5 log acceptability limit or the recalculated acceptability limits. Data also indicated that the RTU device was selective and specific, inhibiting the growth of nine non-target organisms that grew on the reference agar.

Significance: The RTU device gives equivalent results to the ISO reference method 6888-1(2021) for a broad range of foods. This RTU device is a rapid convenient alternative for the enumeration of S. aureus enabling results in 24h.

Outline

Product Easy Plate
Event date 2023.05.03
Session 2023.04.27~2031.04.27

Seminar Detail

Venue Aberdeen, Scotland
Venue Information P&J Live , Aberdeen, Scotland

Related seminars

  • End
  • ATP Test
  • Prepared Media Plate
  • Allergen Testing
  • Histamine assay

The Indonesia International Laboratory Equipment, Analytical Instruments &Services Exhibition 2023 (INALAB 2023)

INALAB 2023 will be held on 23-25 August 2023, and will be co-located with INAPHARM, CHEMICAL INDONESIA, and Food Manufacturing Indonesia at Jakarta International Expo (JIExpo), Kemayoran, Jakarta-Indonesia. Known to be the showcase of the latest Laboratory Equipment and Analytical Instruments for various industies to Indonesia's Laboratories industries and Asia-Pacific Region. Indonesia as the largest market for the laboratory industry in the region is very potential for health-related needs. Based on the introduction of general health insurance in 2014, there is a huge number of Indonesian people who are entitled to health care, which reaches more than 220 million. The health care includes laboratory tests and very soon, all 270 million inhabitants will be entitled to benefit from it. There are nearly 2,900 hospitals in Indonesia. Many of them have 

Seminar 

ATP is the universal energy molecule found in all living things. ATP tests are widely used in all types of food processing plants or in hospitals because they are easy to use and provide immediate feedback and verification of sanitation processess.

Kikkoman Biochemifa Regional Manager Yusei Tsuda will introduce the new generation of ATP test, Lumitester Smart and LuciPac A3-ATP Test (Kikkoman A3). The only system available to detect all three adenylates of ATP (ATP+ADP+AMP or "A3") all in one test. Compared to conventional ATP test that could only detect ATP, ATP Test (Kikkoman A3) is able to detect the degradation of ATP, which most food residues are rich with. 

TOP